Difference between revisions of "Thermal Control System (large)"
m (1.2 changes) |
m (Typo, also outdated info: Nerv's don't overheat during burns anymore) |
||
(5 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | |||
{{:Thermal Control System (large)/Box}} | {{:Thermal Control System (large)/Box}} | ||
+ | [[File:Thermal Control System (large) deployed.png|300px|thumbnail|left|Deployed.]] | ||
− | The '''Thermal Control System (large)''' is a | + | The '''large Thermal Control System ''' is a deployable [[radiator]] used to dissipate waste heat into space (and [[atmosphere]]), pumping it out of hot parts anywhere on the craft, consuming an amount of [[electric charge]] (30 per minute). |
+ | |||
+ | Part heat may be accumulated from external sources (e.g. [[re-entry]] or sunlight from [[Kerbol]]) or be generated by [[reaction engine]]s or the cores of [[resource harvester]] drills or [[converter]]s, while they are active. Radiators make themselves hotter to perform efficiently, but self-limit to avoid heating to destruction. | ||
+ | |||
+ | This radiator only functions while deployed and will be broken off by 2.5 kPa of dynamic pressure (i.e. moving too fast through a fairly thick atmosphere). It can not be used as a structural element, to attach other parts to, unlike the fixed panel radiators. | ||
+ | |||
+ | By far the most capable radiator part, it is suited to large stations or ships, or if venturing close to Sun. | ||
+ | |||
+ | == Core Cooling == | ||
+ | |||
+ | The limiting factor for cooling the cores of drills and converters is the "'''Core Heat xFer'''" (transfer) limit of the radiator: '''1000kW'''. | ||
+ | |||
+ | This is substantially lower than what the part can actually dissipate, under most circumstances, with a "'''Max Cooling'''" figure of: '''85077kW'''. | ||
+ | |||
+ | {{Stats table Core Cooling}} | ||
== Product description == | == Product description == | ||
Line 8: | Line 22: | ||
|A deployable thermal control system consisting of multiple liquid cooled radiator panels. | |A deployable thermal control system consisting of multiple liquid cooled radiator panels. | ||
|Probodobodyne Inc.}} | |Probodobodyne Inc.}} | ||
− | |||
− | |||
== Changes == | == Changes == | ||
Line 18: | Line 30: | ||
{{Parts}} | {{Parts}} | ||
+ | [[Category: Radiators]] |
Latest revision as of 04:26, 10 June 2022
Thermal Control System (large) | ||
Radiator by Probodobodyne Inc | ||
Radial size | Radial mounted | |
Cost | (total) | 9 000.00 |
Mass | (total) | 1.000 t |
Drag | 0.2 | |
Max. Temp. | 2500 K | |
Impact Tolerance | 12 m/s | |
Research | High-Power Electrics | |
Unlock cost | 45 000 | |
Since version | 1.0.3 | |
Part configuration | foldingRadLarge.cfg | |
Electricity required | 0.5 ⚡/s | |
Dissipated heat | 1000 kW [1] | |
Retractable | Yes | |
|
The large Thermal Control System is a deployable radiator used to dissipate waste heat into space (and atmosphere), pumping it out of hot parts anywhere on the craft, consuming an amount of electric charge (30 per minute).
Part heat may be accumulated from external sources (e.g. re-entry or sunlight from Kerbol) or be generated by reaction engines or the cores of resource harvester drills or converters, while they are active. Radiators make themselves hotter to perform efficiently, but self-limit to avoid heating to destruction.
This radiator only functions while deployed and will be broken off by 2.5 kPa of dynamic pressure (i.e. moving too fast through a fairly thick atmosphere). It can not be used as a structural element, to attach other parts to, unlike the fixed panel radiators.
By far the most capable radiator part, it is suited to large stations or ships, or if venturing close to Sun.
Core Cooling
The limiting factor for cooling the cores of drills and converters is the "Core Heat xFer" (transfer) limit of the radiator: 1000kW.
This is substantially lower than what the part can actually dissipate, under most circumstances, with a "Max Cooling" figure of: 85077kW.
To maintain an active drill or converter core at optimal thermal efficiency, radiators must provide enough unused Core Heat Transfer capacity to fulfil the "Required Cooling" stat, shown below:
Image | Part | Required Cooling (kW) | Max Cooling(kW) |
---|---|---|---|
'Drill-O-Matic Junior' Mining Excavator | 50 | 50 | |
'Drill-O-Matic' Mining Excavator | 100 | 100 | |
Convert-O-Tron 125 | 100 | 75* | |
Convert-O-Tron 250 | 200 | 200 |
(*) The Convert-O-Tron 125 is a special case - it can not be maintained at optimal thermal efficiency because its "Max cooling" cap of 75kW is below it's required cooling (100kW). With the help of radiators, it will still reach equilibrium, albeit a little hotter than the optimal 1000K. This is possible because core heat production scales down at higher core temperatures, as the thermal efficiency drops off.
Also note, for both Converters, that the required cooling figure is per active conversion mode, with each unit able to have any, or all, of their four ore conversion modes active at the same time. Hence the Convert-O-Tron 250's required cooling can also exceed its maximum permitted (e.g. 3 modes will produce 600kW of core heating).
Product description
“ | A deployable thermal control system consisting of multiple liquid cooled radiator panels. — Probodobodyne Inc. |
” |
Changes
- Moved from Utility to Thermal
- Initial release