Difference between revisions of "Template:Infobox/Part/radiator"
From Kerbal Space Program Wiki
< Template:Infobox | Part
m (Use correct value for dissipated heat and add note) |
m (Update logic) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
<noinclude>{{Infobox/Part/preview| | <noinclude>{{Infobox/Part/preview| | ||
</noinclude>{{Infobox/Line|{{Infobox/Part/Dict|ele-req}}|{{{require<noinclude>|0.025</noinclude>}}} {{mark|echu}}/{{dict|s}}}} | </noinclude>{{Infobox/Line|{{Infobox/Part/Dict|ele-req}}|{{{require<noinclude>|0.025</noinclude>}}} {{mark|echu}}/{{dict|s}}}} | ||
− | {{Infobox/Line|{{Infobox/Part/Dict|dissipate}}|{{#expr: {{{dissipate|0<noinclude>7500</noinclude>}}}/50}} {{dict|k}}{{dict|W}} {{#tag:ref|{{Infobox/Part/Dict|{{#ifeq: {{lc:{{{parent cooling}}}}}|y| | + | {{Infobox/Line|{{Infobox/Part/Dict|dissipate}}|{{#expr: {{{dissipate|0<noinclude>7500</noinclude>}}}/50}} {{dict|k}}{{dict|W}} {{#tag:ref|{{Infobox/Part/Dict|cooling {{#ifeq: {{lc:{{{parent cooling}}}}}|y|parent|all}} note}}}}}} |
− | {{Infobox/Line|{{Infobox/Part/Dict|retractable}}|{{ | + | {{Infobox/Line|{{Infobox/Part/Dict|retractable}}|{{Boolean|{{{retractable<noinclude>|y</noinclude>}}}|{{No}}}}}}<noinclude> |
{{Infobox/Line|<hr>{{#tag:references}}}}}} | {{Infobox/Line|<hr>{{#tag:references}}}}}} | ||
Line 10: | Line 10: | ||
{{Parameter row|require|The amount of electricity required in {{mark|echu}}/s}} | {{Parameter row|require|The amount of electricity required in {{mark|echu}}/s}} | ||
{{Parameter row|dissipate|How much heat that gets dissipated into space.}} | {{Parameter row|dissipate|How much heat that gets dissipated into space.}} | ||
− | {{Parameter row|parent cooling|Whether the radiator only cools nearby parts or all parts.| | + | {{Parameter row|parent cooling|Whether the radiator only cools nearby parts or all parts. This changes the note that is shown.|cooling all note}} |
− | {{Parameter row|retractable|Whether the radiator panels are retractable.|No}} | + | {{Parameter row|retractable|Whether the radiator panels are retractable.|{{No}}}} |
}} | }} | ||
{{Subcategory|modules}}</noinclude> | {{Subcategory|modules}}</noinclude> |
Latest revision as of 07:29, 17 September 2024
Electricity required | 0.025 ⚡/s | |
Dissipated heat | 150 kW [1] | |
Retractable | Yes | |
|
{{Infobox/Part}} module for radiator panels.
Name | Optional | Description | Default |
---|---|---|---|
require | No | The amount of electricity required in ⚡/s | |
dissipate | No | How much heat that gets dissipated into space. | |
parent cooling | Yes | Whether the radiator only cools nearby parts or all parts. This changes the note that is shown. | cooling all note |
retractable | Yes | Whether the radiator panels are retractable. | No |