Difference between revisions of "Parts/Science/sensorThermometer/sensorThermometer.cfg"
From Kerbal Space Program Wiki
< Parts
Nilesrogoff (talk | contribs) (Page Created) |
(*copy from Parts/Utility/sensorThermometer/part.cfg created by Artorp;) |
||
Line 1: | Line 1: | ||
− | + | {{Part config|2HOT Thermometer|2=PART | |
+ | { | ||
name = sensorThermometer | name = sensorThermometer | ||
module = Part | module = Part | ||
Line 9: | Line 10: | ||
node_attach = 0.0, 0.0, 0.0, 0.0, 0.0, -1.0 | node_attach = 0.0, 0.0, 0.0, 0.0, 0.0, -1.0 | ||
− | cost = | + | TechRequired = spaceExploration |
+ | entryCost = 2200 | ||
+ | cost = 900 | ||
category = Science | category = Science | ||
subcategory = 0 | subcategory = 0 | ||
title = 2HOT Thermometer | title = 2HOT Thermometer | ||
manufacturer = Probodobodyne Inc. | manufacturer = Probodobodyne Inc. | ||
− | description = This thermometer is definetely not a store-bought model with some wires stuck to it. | + | description = This thermometer is definetely not a store-bought model with some wires stuck to it. Warranty void if an engineer admits it's actually a store-bought model with some wires stuck to it. |
attachRules = 0,1,0,0,1 | attachRules = 0,1,0,0,1 | ||
Line 31: | Line 34: | ||
sensorType = TEMP | sensorType = TEMP | ||
} | } | ||
− | + | ||
+ | MODULE | ||
+ | { | ||
+ | name = ModuleScienceExperiment | ||
+ | |||
+ | experimentID = temperatureScan | ||
+ | |||
+ | experimentActionName = Log Temperature | ||
+ | resetActionName = Delete Data | ||
+ | |||
+ | useStaging = False | ||
+ | useActionGroups = True | ||
+ | hideUIwhenUnavailable = False | ||
+ | |||
+ | xmitDataScalar = 0.5 | ||
+ | |||
+ | dataIsCollectable = True | ||
+ | collectActionName = Take Data | ||
+ | interactionRange = 1.2 | ||
+ | |||
+ | rerunnable = True | ||
+ | } | ||
+ | |||
+ | |||
+ | } | ||
+ | |||
+ | }} |
Revision as of 22:42, 25 January 2014
PART { name = sensorThermometer module = Part author = NovaSilisko mesh = model.mu rescaleFactor = 1 node_attach = 0.0, 0.0, 0.0, 0.0, 0.0, -1.0 TechRequired = spaceExploration entryCost = 2200 cost = 900 category = Science subcategory = 0 title = 2HOT Thermometer manufacturer = Probodobodyne Inc. description = This thermometer is definetely not a store-bought model with some wires stuck to it. Warranty void if an engineer admits it's actually a store-bought model with some wires stuck to it. attachRules = 0,1,0,0,1 // --- standard part parameters --- mass = 0.005 dragModelType = default maximum_drag = 0.2 minimum_drag = 0.2 angularDrag = 1 crashTolerance = 8 maxTemp = 3200 MODULE { name = ModuleEnviroSensor sensorType = TEMP } MODULE { name = ModuleScienceExperiment experimentID = temperatureScan experimentActionName = Log Temperature resetActionName = Delete Data useStaging = False useActionGroups = True hideUIwhenUnavailable = False xmitDataScalar = 0.5 dataIsCollectable = True collectActionName = Take Data interactionRange = 1.2 rerunnable = True } }