Difference between revisions of "Grand Slam Passive Seismometer"
(Explain how the amount of science for the seismometer/seismic sensor is calculated.) |
(Fix/improve grammar.) |
||
Line 14: | Line 14: | ||
The fraction of the Seismic Sensor's amount of science that is achieved by an impact is computed as Sensor Readings · Distance Attenuation · Setup. | The fraction of the Seismic Sensor's amount of science that is achieved by an impact is computed as Sensor Readings · Distance Attenuation · Setup. | ||
− | (The seismometer's context menu entry "Science Completed" shows this | + | (The seismometer's context menu entry "Science Completed" shows the sum of this value for all impacts it recorded.) |
The amount of science points generated by an impact is the above fraction times the experiment's total value (80 Points) times the [[Science#Celestial_body_multipliers|celestial body surface science multiplier]]. | The amount of science points generated by an impact is the above fraction times the experiment's total value (80 Points) times the [[Science#Celestial_body_multipliers|celestial body surface science multiplier]]. | ||
For example, an impact with a sensor reading of 40%, an attenuation value of 65% and a setup value of 80% achieves a fraction of 0.4 · 0.65 · 0.8 = 0.208 i.e. 20.8% of the Seismic Sensor's total experiment value. | For example, an impact with a sensor reading of 40%, an attenuation value of 65% and a setup value of 80% achieves a fraction of 0.4 · 0.65 · 0.8 = 0.208 i.e. 20.8% of the Seismic Sensor's total experiment value. | ||
− | If this impact | + | (It would take 5 such impacts to generate the full amount of science that the Seismic Sensor can generate.) |
− | + | If this impact were to happen on Moho (whose surface science multiplicator is 10), the amount of science generated by the impact would be 0.208 · 80 · 10 = 166.4 science points. | |
Line 30: | Line 30: | ||
where the mass is in kg, the speed in m/s, and the energy in Joule. | where the mass is in kg, the speed in m/s, and the energy in Joule. | ||
− | The table for the celestial body | + | The table for the celestial body values is as follows: |
{| class="wikitable" | {| class="wikitable" | ||
Line 98: | Line 98: | ||
=== Setup (Scientist bonus/malus) === | === Setup (Scientist bonus/malus) === | ||
− | The Setup value (which is | + | The Setup value (which is shown as "Science Rate" in the seismometer's context menu) depends on the scientist level of the kerbal that deployed the seismometer, as given by this table: |
{| class="wikitable" | {| class="wikitable" |
Latest revision as of 18:51, 11 May 2024
Available only with the Breaking Ground Expansion installed. |
Grand Slam Passive Seismometer | ||
Environmental sensor by Probodobodyne Inc | ||
Cost | (total) | 4 000.00 |
Mass | (total) | 0.035 t |
Drag | 0.1 | |
Max. Temp. | 1200 K | |
Impact Tolerance | 5 m/s | |
Research | Electronics | |
Unlock cost | 12 000 | |
Since version | 1.7.1 | |
Part configuration | seismicSensor.cfg | |
Experiment | Surface Deployed Seismic Sensor | |
Packed volume | 25 l | |
Power required | 1 unit |
Contents
Product description
“ | This ground-deployed sensor contains very delicate, sophisticated accelerometers meant to detect and analyze the precisely calibrated seismic shock waves generated by smashing rocket parts at high speed into whatever planet or moon it happens to be sitting on. Note: Please allow trained Scientists to deploy for best results. Needs a deployed power unit & central station to operate. — Probodobodyne Inc |
” |
Usage
This is the only deployable science module which doesn't send science points through time. Instead, it works by impacting objects near the seismometer.
Science value calculation
The fraction of the Seismic Sensor's amount of science that is achieved by an impact is computed as Sensor Readings · Distance Attenuation · Setup.
(The seismometer's context menu entry "Science Completed" shows the sum of this value for all impacts it recorded.)
The amount of science points generated by an impact is the above fraction times the experiment's total value (80 Points) times the celestial body surface science multiplier.
For example, an impact with a sensor reading of 40%, an attenuation value of 65% and a setup value of 80% achieves a fraction of 0.4 · 0.65 · 0.8 = 0.208 i.e. 20.8% of the Seismic Sensor's total experiment value. (It would take 5 such impacts to generate the full amount of science that the Seismic Sensor can generate.) If this impact were to happen on Moho (whose surface science multiplicator is 10), the amount of science generated by the impact would be 0.208 · 80 · 10 = 166.4 science points.
Sensor Readings
The "Sensors Readings" value is the kinetic energy of the impactor divided by an energy value specific to the celestial body. The kinetic energy is calculated as follows: where the mass is in kg, the speed in m/s, and the energy in Joule.
The table for the celestial body values is as follows:
Body | Value |
---|---|
Moho | 2.02e9J |
Eve | 9.78e10J |
Gilly | 1e6J |
Kerbin | 4.184e10J |
Mun | 7.82e8J |
Minmus | 2.12e7J |
Duna | 3.62e9J |
Ike | 2.23e8J |
Dres | 2.58e8J |
Laythe | 2.36e10J |
Vall | 2.49e9J |
Tylo | 3.39e10J |
Bop | 2.99e7J |
Pol | 8.66e6J |
Eeloo | 8.94e8J |
For example a 4.5t impactor hitting at 1000m/s has an energy of 0.5 · 4500kg · 1000m/s ^ 2 = 2.25e9J .
On Moho this gives a sensor reading of 2.25e9J / 2.02e9J = 1.11 i.e. 111%.
Distance Attenuation
The attenuation value depends on the distance of the impact point from the seismometer. It starts at 0% for a distance of zero meters, rises sharply to a maximum of 100% at a distance of 0.02 times the radius of the celestial body and then declines (slowlier) with further increasing distance. Erring towards a greater distance will result in a smaller decrease of the attenuation value than erring the same amount towards a smaller distance. For example on Moho with a radius of 250km the optimal distance is 0.02 · 250km = 5km, but a distance of 7km will also still result in an attenuation value of 100%.
Setup (Scientist bonus/malus)
The Setup value (which is shown as "Science Rate" in the seismometer's context menu) depends on the scientist level of the kerbal that deployed the seismometer, as given by this table:
Level | Value |
---|---|
Not scientist | 0.05 |
Level 0 | 0.25 |
Level 1 | 0.35 |
Level 2 | 0.45 |
Level 3 | 0.60 |
Level 4 | 0.80 |
Level 5 | 1.00 |
This multiplier influences how much science is generated by each impact but not the total amount of science that the experiment can generate.
The total amount of science is as follows: base value of the module (80) · body surface science multiplier
Changes
- Initial Release
|