Fuel tank
A liquid fuel tank holds liquid fuel required for powering rocket engines and jet engines.
Contents
Overview
A liquid fuel tank can provide fuel to any engine directly attached to it. When tanks are directly connected together in a stack they will feed fuel from the top tank first, automatically switching to the next tank as they empty. You can mount additional fuel tanks with radial decouplers, and the use fuel lines to provide fuel into the central tanks. This can be used to provide an asparagus staging system where outer tanks are drained first, then dumped leaving central tanks completely full. This can be tricky to get set up when dealing with very large rockets as the rocket engines of the outer layers need to be kept running long enough to ensure the rest of the rocket can get into orbit once they have stopped providing thrust.
Real world application
In real spacecraft, the fuel tanks store both fuel, usually highly refined kerosene for the first stage and/or liquid hydrogen (LH2) for subsequent stages, and an oxidizing agent, such as liquid oxygen (LOX). Both the fuel and oxidizing agent are stored under slight pressure in special fuel tanks to keep them from vaporizing; this is because LH2 and LOX require temperatures below 20.28 K (−252.87 °C, −423.17 °F) and 90.19 K (−182.96 °C, −297.33 °F) respectively to remain in a liquid state. In comparison, jet aircraft carry only fuel as real jet engines can rely solely on atmospheric oxygen as an oxidizer. Most jet engines operate using a refined kerosene hydro-carbon, similar to diesel, which can actually be used in some diesel engines. However, it is not recommended, or legal in some places, to use jet fuel as a replacement for diesel due to its high lead content and lesser lubricating ability.
Dedicated fuel tanks
Liquid fuel and oxidizer density are both 5 kg/unit | Mass (t) |
Liquid Fuel () |
Oxidizer () | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Image | Part | Radial size | Cost () |
Full | Empty | Max. Temp. (K) |
Tolerance (m/s) |
Tolerance (g) | ||
R-4 'Dumpling' External Tank | X | 50 (39.90) |
0.1238 | 0.0138 | 2 000 | 5 | 50 | 9.9 | 12.1 | |
R-11 'Baguette' External Tank | X | 50 (25.21) |
0.3038 | 0.0338 | 2 000 | 5 | 50 | 24.3 | 29.7 | |
R-12 'Doughnut' External Tank | Small | 147 (119.46) |
0.3375 | 0.0375 | 2 000 | 6 | 50 | 27 | 33 | |
Oscar-B Fuel Tank | Tiny | 70 (51.64) |
0.225 | 0.025 | 2 000 | 6 | 50 | 18 | 22 | |
FL-T100 Fuel Tank | Small | 150 (104.1) |
0.5625 | 0.0625 | 2 000 | 6 | 50 | 45 | 55 | |
FL-T200 Fuel Tank | Small | 275 (183.2) |
1.125 | 0.125 | 2 000 | 6 | 50 | 90 | 110 | |
FL-T400 Fuel Tank | Small | 500 (316.4) |
2.25 | 0.25 | 2 000 | 6 | 50 | 180 | 220 | |
FL-T800 Fuel Tank | Small | 800 (432.8) |
4.5 | 0.5 | 2 000 | 6 | 50 | 360 | 440 | |
Rockomax X200-8 Fuel Tank | Large | 800 (432.8) |
4.5 | 0.5 | 2 000 | 6 | 50 | 360 | 440 | |
Rockomax X200-16 Fuel Tank | Large | 1 550 (815.6) |
9 | 1 | 2 000 | 6 | 50 | 720 | 880 | |
Rockomax X200-32 Fuel Tank | Large | 3 000 (1 531.2) |
18 | 2 | 2 000 | 6 | 50 | 1 440 | 1 760 | |
Rockomax Jumbo-64 Fuel Tank | Large | 5 750 (2 812.4) |
36 | 4 | 2 000 | 6 | 50 | 2 880 | 3 520 | |
Kerbodyne S3-3600 Tank | Extra large | 3 250 (1 597.6) |
20.25 | 2.25 | 2 000 | 6 | 50 | 1 620 | 1 980 | |
Kerbodyne S3-7200 Tank | Extra large | 6 500 (3 195.2) |
40.5 | 4.5 | 2 000 | 6 | 50 | 3 240 | 3 960 | |
Kerbodyne S3-14400 Tank | Extra large | 13 000 (6 390.4) |
81 | 9 | 2 000 | 6 | 50 | 6 480 | 7 920 | |
Mk2 Rocket Fuel Fuselage Short | Mk2 | 750 (566.4) |
2.29 | 0.29 | 2 500 | 50 | 50 | 180 | 220 | |
Mk2 Rocket Fuel Fuselage | Mk2 | 1 450 (1 082.8) |
4.57 | 0.57 | 2 500 | 50 | 50 | 360 | 440 | |
Mk3 Rocket Fuel Fuselage Short | Mk3 | 2 500 (1 352.5) |
14.29 | 1.79 | 2 700 | 50 | 50 | 1 125 | 1 375 | |
Mk3 Rocket Fuel Fuselage | Mk3 | 5 000 (2 705) |
28.57 | 3.57 | 2 700 | 50 | 50 | 2 250 | 2 750 | |
Mk3 Rocket Fuel Fuselage Long | Mk3 | 10 000 (5 410) |
57.14 | 7.14 | 2 700 | 50 | 50 | 4 500 | 5 500 | |
C7 Brand Adapter - 2.5m to 1.25m | Small, Large | 800 (433.0) |
4.57 | 0.57 | 2 300 | 20 | 50 | 360 | 440 | |
C7 Brand Adapter Slanted - 2.5m to 1.25m | Small, Large | 800 (433.0) |
4.57 | 0.57 | 2 300 | 20 | 50 | 360 | 440 | |
Mk2 to 1.25m Adapter | Small, Mk2 | 550 (366.4) |
2.29 | 0.29 | 2 500 | 50 | 50 | 180 | 220 | |
Mk2 to 1.25m Adapter Long | Small, Mk2 | 1 050 (682.8) |
4.57 | 0.57 | 2 500 | 50 | 50 | 360 | 440 | |
Mk2 Bicoupler | Small, Mk2 x 2 | 860 (676.4) |
2.29 | 0.29 | 2 500 | 50 | 50 | 180 | 220 | |
2.5m to Mk2 Adapter | Large, Mk2 | 800 (432.8) |
4.57 | 0.57 | 2 500 | 50 | 50 | 360 | 440 | |
Mk3 to Mk2 Adapter | Mk2, Mk3 | 2 200 (1 282.0) |
11.43 | 1.43 | 2 600 | 50 | 50 | 900 | 1 100 | |
Mk3 to 2.5m Adapter | Large, Mk3 | 2 500 (1 353.0) |
14.29 | 1.79 | 2 600 | 50 | 50 | 1 125 | 1 375 | |
Mk3 to 2.5m Adapter Slanted | Large, Mk3 | 2 500 (1 353.0) |
14.29 | 1.79 | 2 600 | 50 | 50 | 1 125 | 1 375 | |
Mk3 to 3.75m Adapter | Extra large, Mk3 | 2 500 (1 353.0) |
14.29 | 1.79 | 2 600 | 50 | 50 | 1 125 | 1 375 | |
Kerbodyne ADTP-2-3 | Large, Extra large | 1 623 (246.0) |
16.88 | 1.88 | 2 000 | 6 | 50 | 1 350 | 1 650 |
Note: Not only are the above four dedicated fuel tanks, but there is also a selection of fuselage parts which serve to hold fuel. These fuselage parts are intended for space planes and/or shuttles, but can be used as part of normal rocket if desired (see fuselage fuel tanks)
Fuselage fuel tanks
Liquid Fuel Density is 5 kg/unit | Mass (t) |
Liquid Fuel () | |||||||
---|---|---|---|---|---|---|---|---|---|
Image | Part | Radial size | Cost () |
Full | Empty | Max. Temp. (K) |
Tolerance (m/s) |
Tolerance (g) | |
Engine Nacelle[Note 1] | Small | 600 (480) |
0.925 | 0.15 | 2 000 | 10 | 50 | 150 | |
Engine Pre-cooler[Note 1] | Small | 1 650 (1 618) |
0.375 | 0.15 | 2 000 | 10 | 50 | 40 | |
Mk1 Diverterless Supersonic Intake[Note 1] | Small | 720 (560) |
1.18 | 0.17 | 2 000 | 10 | 50 | 200 | |
Mk0 Liquid Fuel Fuselage | Tiny | 200 (160) |
0.275 | 0.025 | 2 000 | 10 | 50 | 50 | |
Mk1 Liquid Fuel Fuselage | Small | 550 (230) |
2.25 | 0.25 | 2 000 | 10 | 50 | 400 | |
Mk2 Liquid Fuel Fuselage Short | Mk2 | 750 (430) |
2.29 | 0.29 | 2 500 | 50 | 50 | 400 | |
Mk2 Liquid Fuel Fuselage | Mk2 | 1 450 (810) |
4.57 | 0.57 | 2 500 | 50 | 50 | 800 | |
Mk3 Liquid Fuel Fuselage Short | Mk3 | 4 300 (2 300) |
14.29 | 1.79 | 2 700 | 50 | 50 | 2 500 | |
Mk3 Liquid Fuel Fuselage | Mk3 | 8 600 (4 600) |
28.57 | 3.57 | 2 700 | 50 | 50 | 5 000 | |
Mk3 Liquid Fuel Fuselage Long | Mk3 | 17 200 (9 200) |
57.14 | 7.14 | 2 700 | 50 | 50 | 10 000 | |
NCS Adapter | Small, Tiny | 320 (256) |
0.5 | 0.1 | 2 400 | 10 | 50 | 80 | |
FAT-455 Aeroplane Main Wing[Note 2] | X | 2 800 (2 320) |
3.78 | 0.78 | 1 200 | 15 | 50 | 600 | |
Big-S Wing Strake[Note 2] | X | 1 000 (920) |
0.6 | 0.1 | 2 400 | 15 | 50 | 100 | |
Big-S Delta Wing[Note 2] | X | 3 000 (2 760) |
2.0 | 0.5 | 2 400 | 15 | 50 | 300 |
- ↑ 1.0 1.1 1.2 The Engine Nacelle, Engine Pre-cooler, and Mk1 Diverterless Supersonic Intake are a combination of air intake and liquid fuel tank. Only the tank properties are shown. They are located in the "Aerodynamic" category in the game.
- ↑ 2.0 2.1 2.2 The FAT-455 Aeroplane Main Wing, Big-S Wing Strake, and Big-S Delta Wing are a combination of lifting surface and liquid fuel tank. Only the tank properties are shown. They are located in the "Aerodynamic" category in the game.
Note: In general, fuselage fuel tanks weigh less and hold notably less fuel when compared to dedicated fuel tanks, but can be used to power most jet engines for more than a few minutes. On the other hand, a rocket engine will empty a fuselage fuel tank in mere seconds!
Modder's resource
The fuel/dry/full mass of dedicated fuel tanks are associated with the following formulas. This assume that the game values are given in liters (1 L = 1 dm³ = 0.001 m³) and metric tons (1 t = 1 Mg = 1000 kg).
Take the Rockomax X200-16 Fuel Tank for example. Based on some rough in-game measurements it is approximately 0.67 meters tall with a radius of 1 meter. This would give the tank/stage a real world volume of around 2094.4 liters (2.0944 m³). Dividing the tank's actual in-game fuel capacity (0.72 m³ + 0.88 m³ = 1.6 m³) by its total volume we can find what percentage of the volume is used for fuel, around 76.39%, very close to the roughly 80% for the Saturn V's stages. The reason the entire volume is not used is because the actual fuel tank is a pressure vessel with rounded ends inside the cylindrical stage.
Notes
- As of v0.17 all fuel tanks still provide fuel for both rocket engines and jet engines, being that there is currently only one type of fuel recognized in game.
- It should be noted though that RCS uses its own type of fuel that is separate to Rocket/Jet fuel.